Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Pulse Oximeter
Still deciding? Get samples of US$ 160/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
60
Year of Establishment
1994-05-12
  • Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
  • Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
  • Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
  • Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
PM-600A
Certification
ISO13485
Product
Handheld Pulse Oximeter
Item
Pm-600A
Monitor
SpO2,Temp, Pr and Pleth
Power
Built-in Rechargeable Li-ion Battery
Transport Package
Carton
Specification
18*16*10cm
Trademark
Dongjiang
Origin
Guangdong, China

Product Description

Product Description

Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth

Product Parameters

Power Requirements
Battery:
-- Type: 3.7v Li-ion rechangeble battery
-- Operating time: 15 hours
-- Rechange time: 8 hours
AC power adapter:
-- Input: AC100 - 240V, 50/60Hz, 5VA
-- Output: D.C. 5V


Display
-- 2.8" 240×320dot matrix color TFT LCD

Operating Environment
-- Temperature: 0 ~ 45 ºC
-- Humidity: 15% ~ 95% (non-condensing)
-- Altitude: 86 KPa ~ 106 KPa

Transportation and Storage Environment
-- Temperature: -20 ~ 60 ºC
-- Humidity: 10% ~ 95% (non-condensing)
-- Altitude: 50 KPa ~ 106 KPa
 
Temperature(TEMP)
-- Channel: 1
-- Input: Skin surface thermal-sensitive resistor temperature sensor
-- Measurement Range: 0 ~ 50 ºC
-- Resolution: 0.1 ºC
-- Accuracy: ±0.2 ºC
 
SpO2
-- Patient Type: Adult, Pediatric, Neonatal
-- Measurement Range: 0 ~ 100 %
-- Resolution: 1 %
-- Accuracy: ±2 % (70% ~ 100%)
Unspecified (0 ~ 69%)
Pulse Rate
-- Measurement Range: 0 bpm ~ 250 bpm
-- Resolution: 1 bpm
-- Accuracy: ±2 bpm

 
Detailed Photos
Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth
Packaging & Shipping

Dimension and Net Weight
Dimension: 120*60*28 mm
Net Weight: 200g


Package list:
1* PM-600A Handheld Pulse Oximeter
1* User manual 

1* SpO2 sensor
1* Temp Probe
1* USB Cable

Packing: 1pc/box, box size: 
18*16*10 cmPortable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth

Company Profile

Portable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and PlethPortable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and PlethPortable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and PlethPortable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and PlethPortable Handheld Pulse Oximeter Adult Paediatric Neonatal SpO2, Temp, Pr and Pleth

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier