Model PM-600C: SpO2 and Pr Big Screen 3.5" Color TFT LCD Handheld Pulse Oximeter
CMICS is specialized in professional manufacturing and export of medical devices with more than 40 years experience in the fields of cardiology, patient monitoring, healthcare, veterinary as well the related consumable/disposable items. We also act as one stop supplier of medical devices.
Particularly, as an important part of the healthcare producline, here is the Handheld Pulse Oximeter (Pulse Oximeter, Oximeter, Finger Pulse Oximeter, Fingertip Pulse Oximeter, Handheld Pulse Oximeter), model PM-600C, whih is applicable to adult, pediatric and neonatal. It can be widely used in different situations, such as home, clinic, bedside as well ambulance to play essential role in healtcare montoring for SPO2, PR and PI.
Features
| Light weight for carrying and eaay to use |
| D89 type connector compatible with other SPO2 sensor |
| Support the oximeter probe for adult, pediatric and neonate |
| Big size 3.5 inch colot TFT LCD display for SPO, PR, PI (perfusion index), pulse bargraph and plethysmogram |
| Three levels of visual and audible alarm |
| Low battery voltage indication |
| Automatical switch off within 3 minutes whenno signal |
| Large internal flash memory can store test reults |
| Standard 3.7 V 2600 mA rechargeable Lithium battery for power supply |
Technical Data

| Power Supply | Voltage: DC 5V, IA adaptor |
| Power Consumption: ≤ 195mA | |
| Battery | Type: 3.7V 2600mA rechargeable lithium battery |
| 8-hour continuous operation with a new, fully charged battery | |
| Display | 3.5 inch colot TFT LCD |
| Operating Environment | Temperature: 5 ~ 40 ºC |
| Humidity: 15% ~ 80% (non-condensing) | |
| Atmosphere pressure: 86 KPa ~ 110 KPaAtmosphere pressure: 86 KPa ~ 110 KPa | |
| Transportation and Storage Environment | Temperature: -20 ~ 50 ºC |
| Humidity: 15% ~ 80% (non-condensing) | |
| Atmosphere pressure: 86 KPa ~ 110 KPa | |
| Pulse Rate | Measuring and Alarm Range: 25 ~ 250 bpm |
| Accuracy: ±1% or ±1 bpm, whichever is greater | |
| Resolution: 1 bpm | |
| SpO2 | Patient Type: Adult, Pediatric, Neonatal |
| Measurement Range: 0 ~ 100 % | |
| Resolution: 1 % | |
| Accuracy: ±2 % (80% ~ 100%), ±3 % (70% ~ 79%), unspecified (0 ~ 69%) | |
| PI range: 0.075% ~ 20% |






Packing: 1pc/box
Standard Package list
| Item | Description | QTY |
| 1 | PM-600C Handheld Pulse Oximeter | 1 |
| 2 | SpO2 sensor | 1 |
| 3 | USB Cable | 1 |
| 4 | User manual | 1 |
Optional Package list:
1 Pediatric Finger / Toe SpO2 Sensor