Product Description
Veterinary Monitor with 8 inch Touch Screen and Competitiveness
Model: VM 8
8 inch high brightness (800x600) colorful TFT LCD |
Simultaneous display of 7 lead ECG waveform |
Indented menu layout to maximize the space for display |
Protection against defibrillation and ESU interference |
New SPO2 technology to assure precise measurement |
recise SPO2 measurement for low prefusion |
Analysis of real time ST segment arrhythmia |
Able to analyze 15 kinds of drug level |
168 hour graphic and tabular trend with data storage |
High efficient power management without electric fan |
Up to 66 beds for networking capacity to connect with HIS |
750 group NIBP data for recall and display |
|
Detailed Photos
Product Parameters
ECG
Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 3 channel
Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto
HR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1 bpm, whichever greater
Resolution: 1 bpm
Sensitivity: > 200 (uVp-p)
Differential Input Impedance: > 5 MΩ
CMRR: Monitor: > 110 dB, Operation: > 110 dB, Diagnosis: > 90 dB
Electrode offset Potential: ± 300 mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 seconds after defibrillation
ECG Signal Range: ±8 mV (Vp-p)
Bandwidth:Surgery: 1 ~ 20 Hz, Monitor: 0.5 ~ 40 Hz, Diagnostic: 0.05 ~ 130 Hz
Calibration Signal: 1 (mVp-p), accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mV
Alarm: Available
Review: Available
SpO2
Measurement Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified
Actualization interval: about 1 second
Alarm Delay: 10 second
Pulse Rate Measurement and Alarm Range: 20 ~ 250 bpm
Resolution: 1 bpm
Accuracy: ± 3 bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes)
Measurement Period in STAT Mode: 5 minutes
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measurement and Alarm Range
Adult Mode: SYS: 40 ~ 280 mmHg, DIA: 10 ~ 220 mmHg, MEAN: 20 ~ 240 mmHg
Pediatric Mode: SYS: 40 ~ 220 mmHg, DIA: 10 ~ 160 mmHg, MEAN: 20 ~ 170 mmHg
Neonatal Mode: SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg
Static pressure accuracy: ±3 mmHg
Accuracy: Pressure
Maximum Mean error: ±5 mmHg
Maximum Standard deviation: ±8 mmHg
Overpressure Protection
Adult Mode: 297 ± 3 mmHg
Pediatric Mode: 240 ± 3 mmHg
Neonatal Mode: 147 ± 3 mmH
Respiration
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measurement Impedance Range: 0.3~3.0 Ω
Baseline Impedance Range: 200 - 4000 Ω
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: 0~6 BrPM: unspecified
7~150 BrPM: ±2 BrPM
Apean Alarm: 10 ~ 40 S
Temperature
Channel: 1
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1 °C
Accuracy: ± 0.1 °C
Actualization interval: about 1 second
Average Time Constant: < 10 second
Packaging & Shipping
Package
Dimension: 1 unit in one carton of 25 x 27 x 20 cm
Gross Weight: 4 Kg
Package list
1. Main unit VM 8 Veterinary Monitor
2. ECG Cable(3 Lead)
3. ECG Electrodes
4. SPO2 Sensor
5. NIBP Cuff
6. Extension tube
7. Power Wire
8. Grounding cable
9. User manual
10. Warranty
11. Certificate of Qualification
Shipping
Company Profile