Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Still deciding? Get samples of US$ 320/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hospital Equipment Portable Patient/Cardiac Monitor with ISO13485Patient monitor Features
* 8 inch high brightness (800x600) colorful TFT LCD
* Simultaneous display of 7 lead ECG waveform
* Indented menu layout to maximize the space for display
* Protection agasint defibrillation and ESU interference
* New SPO2 technology to assure precise measurement
* Precise SPO2 measurement for low prefusion & finger motion
* Analysis of real time ST segment arrhythmia
* Able to analyze 15 kinds of drug level
* 168 hour graphic and tabular trend with data storage
* High efficient power management without electric fan to avoid cross contamination
* Up to 66 beds for networking capacity to connect with HIS
* 750 group NIBP data for recall and display
*Standard configuration: ECG, NIBP, SpO2, PR, RESP., TEMP., HR,
*Optional configuration: 1/2/4 IBP, EtCO2, multi gas, CO, 12 lead ECG, thermal recorder, touch screen, WiFi, USB, VGA, SunTech NIBP
ECGLead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selection: I, II, III, avR, avL, avF, V, Waveform: 3 channel Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto HR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm Accuracy: ± 1% or ± 1 bpm, whichever greater Resolution: 1 bpm Sensitivity: > 200 (uVp-p) Differential Input Impedance: > 5 MΩ CMRR: Monitor: > 110 dB, Operation: > 110 dB, Diagnosis: > 90 dB Electrode offset Potential: ± 300 mV Leakage Current: < 10 uA Baseline Recovery: < 3 seconds after defibrillation ECG Signal Range: ±8 mV (Vp-p) Bandwidth:Surgery: 1 ~ 20 Hz, Monitor: 0.5 ~ 40 Hz, Diagnostic: 0.05 ~ 130 Hz Calibration Signal: 1 (mVp-p), accuracy: ±5% ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mV Alarm: Available Review: Available |
SpO2Measurement Range: 0 ~ 100 %Alarm Range: 0 ~ 100 % Resolution: 1 % Accuracy: 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified Actualization interval: about 1 second Alarm Delay: 10 second Pulse Rate Measurement and Alarm Range: 20 ~ 250 bpm Resolution: 1 bpm Accuracy: ± 3 bpm |
NIBPMethod: OscillometricMode: Manual, Auto, STAT Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes) Measurement Period in STAT Mode: 5 minutes Pulse Rate Range: 40 ~ 240 bpm Alarm Type: SYS, DIA, MEAN Measurement and Alarm Range Adult Mode: SYS: 40 ~ 280 mmHg, DIA: 10 ~ 220 mmHg, MEAN: 20 ~ 240 mmHg Pediatric Mode: SYS: 40 ~ 220 mmHg, DIA: 10 ~ 160 mmHg, MEAN: 20 ~ 170 mmHg Neonatal Mode: SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg
Static pressure accuracy: ±3 mmHg
Accuracy: PressureMaximum Mean error: ±5 mmHg Maximum Standard deviation: ±8 mmHg Overpressure Protection Adult Mode: 297 ± 3 mmHg Pediatric Mode: 240 ± 3 mmHg Neonatal Mode: 147 ± 3 mmH |
RespirationMethod: Impedance between R-F (RA-LL)Differential Input Impedance: >2.5 MΩ Measurement Impedance Range: 0.3~3.0 Ω Baseline Impedance Range: 200 - 4000 Ω Bandwidth: 0.3 ~ 2.5 Hz Resp. Rate Measurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm Resolution: 1 rpm Accuracy: 0~6 BrPM: unspecified 7~150 BrPM: ±2 BrPM Apean Alarm: 10 ~ 40 S |
TemperatureChannel: 1Measuring and Alarm Range: 0 ~ 50 °C Resolution: 0.1 °C Accuracy: ± 0.1 °C Actualization interval: about 1 second Average Time Constant: < 10 second |
Product dimension & weight
Length×Width×Height: 212mm×172mm×80mm
Weight: 2 Kg
Package list:
1* PM-300A Patient Monitor
1* ECG Cable(5 Lead)
1* ECG Electrodes
1* SpO2 Probe
1* NIBP Cuff
1* Temp Probe
1* Extension tube
1* Power Wire
1* Grounding cable
1* User manual
1* Warranty
1* Certificate of Qualification
Packing: 1pc/carton, size: 25*27*20cm