Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Still deciding? Get samples of US$ 255/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features
* 2.8 inch color LCD to display SpO2 waveform and PR strength
* 3888 groups storage/review trend data with duration selectable
* Audible & visual alarm
* USB interface for PC connection to support tele-monitoring
* Built-in rechargeable battery with Max. 5 hour operation time
* Automatic power off in case no operation within the preset time
* Applicable to adult, pediatric and neonate
* Indicator with related prompt in case of low battery capacity
Model Configuration
* Standard Configuration: SpO2, PR, NIBP, HR, PLETH
1. General Specifications:
Size: 205mm×200mm×95mm
Net Weight: 1 kg
Display Specification
Parameter Display: 7-segment LEDs
Information Display: Fixed characters and icons lighted by single-color LEDs
Power Supply Indicator: Dual-color LED
2.Power Supply
AC Power Adaptor
Input: AC100-240V, 50/60Hz
Output: DC 9V, 800mA
Battery
Lithium-ion rechargeable 5AHr 7.2V battery
Operating Time: 10 hours with full battery capacity.
( Condition: 25ºC, NIBP working period is 10 minutes. )
Recharge Time: 12 hours.
3. Environment
Temperature
Working: 0 ~ 45 °C
Transport and Storage: -25 ~ 85°C
Humidity
Working: 30 ~ 85 %
Transport and Storage: 30 ~ 95 % (no condensation)
4.Monitoring Parameter
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range: 0 ~ 300 mmHg
Pulse Rate Range: 30~ 250 bpm
Measurement Rage: Adult 30~ 255mmHg, Pediatric 30~ 160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using
cuff and stethoscope. The MEAN value measured using this device is equal to that measured using end artery blood pressure
measurement device.
SpO2
SpO2
Measuring Range: 35 ~ 99%
Resolution: 1 %
Accuracy: ±2 % (70 ~ 99%), unspecified (0~ 69%)
Pulse Rate
Measuring and Alarm Range: 0 ~250bpm
Resolution: 1bpm
Accuracy: ±1bpm
Storage and Review
Storage Method: Store NIBP and SPO2 data each time after one NIBP measurement.
Maximum Store Data of 800 groups.
5. Printer (optional)
Type: Thermal micro-printer
Record Width: 57 mm
Recording Types: Real-time printing and review data printing
AC Power Adaptor
Input: 100 ~ 240V, 50/60Hz
Output: DC 5V, 3A
Package list:
Standard Packing List | |
patient monitor main unit | 1 pc |
Adult finger SpO2 sensor | 1 pc |
Adult NIBP cuff | 1 pc |
NIBP extension tube | 1 pc |
AC power adaptor | 1 pc |
The operator's manual | 1 pc |
Selectable Accessory | |
Child finger SpO2 sensor | |
Child NIBP cuff |
2.8 Inch Medical NIBP SpO2 Portable Vital Sign Monitor