Model: VM 8
Features |
12.1 inch high brightness LCD monitor |
Mirror display with new visual effect and more intimate protection |
Multiple working mode: diagnostic, monitoring, surgery |
Suitable for different pets with different size |
Multiple display mode: standard, large font, trend graph, BP list, etc |
Supporting multi lead display of ECG waveforms at same screen |
Equipped with multiple analysis functions |
Quick setup alarm function |
Bulit in high capacity Lithium batter wth long standby time |
Multi scenario test adaptable to changing environment |
Special algorithm for fast & accurate NIBP meausrement |
SPO2 with advanced anti-interfreance and weak perfusion |
Patented ECG algorithm for multiple arrhythmia identification |
Low power design for power saving and duration |
Standard configuration: ECG, NIBP, SpO2, RESP., TEMP., HR |
Optional configuration: IBP, side stream EtCo2, printer, trolley |
Veterinary Monitor for vital sign monitoring of ECG, NIBP, SPO2, HR with dog, cat, etc |
12.1 inch high brightness LCD monitor, with optional touch screen |
Multiple display mode including standard and large font |
ECG cable of 3 lead |
Disposable NIBP cuff
|
SPO2 sensor |
ECG |
Lead Mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) |
Lead selection | I, II, III, avR, avL, avF, V, |
Waveform | 3 channel |
Gain | 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, auto |
HR and Alarm Range |
Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm |
Accuracy | ± 1% or ± 1 bpm, whichever greater |
Resolution | 1 bpm |
Sensitivity | > 200 (uVp-p) |
Input Impedance | > 5 MΩ |
CMRR | Monitor: > 110 dB, Operation: > 110 dB, Diagnosis: > 90 dB |
Polarizing Voltage | ± 300 mV |
Leakage Current | < 10 uA |
Baseline Recovery | < 3 seconds after defibrillation |
ECG Signal Range | ±8 mV (Vp-p) |
Bandwidth | Surgery: 1 ~ 20 Hz, Monitor: 0.5 ~ 40 Hz, Diagnostic: 0.05 ~ 130 Hz |
Calibration Signal | 1 (mVp-p), accuracy: ±5% |
ST Segment Monitoring Range | Measure and Alarm: -2.0 ~ +2.0 mV |
Alarm | Available |
Review | Available |
SpO2 |
Measurement Range | 0 ~ 100 % |
Alarm Range | 0 ~ 100 % |
Resolution | 1 % |
Accuracy | 70% ~ 100%: ±2 %, 0% ~ 69%: unspecified |
Actualization interval | about 1 second |
Alarm Delay | 10 second |
HR Measurement and Alarm Range | 20 ~ 250 bpm |
Resolution | 1 bpm |
Accuracy | ± 3 bpm |
NIBP |
Method | Oscillometric |
Mode | Manual, Auto, STAT |
Measurement Interval in AUTO Mode | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes) |
Measurement Period in STAT Mode | 5 minutes |
Pulse Rate Range | 40 ~ 240 bpm |
Alarm Type | SYS, DIA, MEAN |
Measurement and Alarm Range | Adult Mode: SYS: 40 ~ 280 mmHg, DIA: 10 ~ 220 mmHg, MEAN: 20 ~ 240 mmHg |
Pediatric Mode: SYS: 40 ~ 220 mmHg, DIA: 10 ~ 160 mmHg, MEAN: 20 ~ 170 mmHg | |
Neonatal Mode: SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHg | |
Static pressure accuracy | ±3 mmHg |
Accuracy | Maximum Mean error: ±5 mmHg Maximum Standard deviation: ±8 mmHg |
Overpressure Protection | Adult Mode: 297 ± 3 mmHg |
Pediatric Mode: 240 ± 3 mmHg | |
Neonatal Mode: 147 ± 3 mmH |
Respiration |
Method | Impedance between R-F (RA-LL) |
Input Impedance | >2.5 MΩ |
Measurement Impedance Range | 0.3~3.0 Ω |
Baseline Impedance Range | 200 - 4000 Ω |
Bandwidth | 0.3 ~ 2.5 Hz |
Measurement and Alarm Range | Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpm |
Resolution | 1 rpm |
Accuracy | 0~6 BrPM: unspecified 7~150 BrPM: ±2 BrPM |
Apean Alarm | 10 ~ 40 S |
Temperature |
Channel | 1 |
Measuring and Alarm Range | 0 ~ 50 °C |
Resolution | 0.1 °C |
Accuracy | ± 0.1 °C |
Actualization Interval | about 1 second |
Average Time Constant | < 10 second |
Package
Dimension: 25 x 27 x 20 cm
Gross Weight: 4 Kg
Packing List
1. Main Unit VM 8 Veterinary Monitor
2. ECG Cable(3 Lead)
3. ECG Electrodes
4. SPO2 Sensor
5. NIBP Cuff
6. Extension tube
7. Power Wire
8. Grounding cable
9. User manual
10. Warranty
11. Certificate of Qualification
Shipping